In Medical Physics, X-ray Imaging Physics covers X-ray production, photon interactions, detector physics, image formation, image quality, dosimetry, instrumentation, and clinical imaging systems.
Nature and properties of X-rays
Electromagnetic spectrum
Photon energy, wavelength, and frequency
X-ray attenuation
Linear attenuation coefficient
Mass attenuation coefficient
Half-value layer (HVL)
Tenth-value layer (TVL)
Beer–Lambert law
X-ray tube physics
Cathode and anode
Thermionic emission
Electron acceleration
Bremsstrahlung radiation
Characteristic X-rays
X-ray emission spectrum
Tube voltage (kVp)
Tube current (mA)
Exposure time
mAs
Tube efficiency
Anode material
Tungsten targets
Rotating anode
Stationary anode
Line-focus principle
Heel effect
Focal-spot size
Tube loading
Heat production and dissipation
High-voltage generation
Single-phase generators
Three-phase generators
High-frequency generators
Voltage ripple
Rectification
Exposure control circuits
Automatic exposure control (AEC)
X-ray beam intensity
Beam quality
Beam quantity
Beam hardening
Inherent filtration
Added filtration
Aluminum filtration
Copper filtration
Collimation
Field-size limitation
Inverse-square law
X-ray fluence
Energy fluence
Photoelectric effect
Compton scattering
Coherent scattering
Rayleigh scattering
Pair production at high photon energies
Photon absorption
Photon scattering
Secondary radiation
Dependence on atomic number
Dependence on photon energy
Tissue attenuation
Differential attenuation
Subject contrast
Image contrast
Radiographic density
Projection geometry
Magnification
Geometric unsharpness
Focal-spot blur
Shape distortion
Spatial resolution
Contrast resolution
Source-to-image distance (SID)
Source-to-object distance (SOD)
Object-to-image distance (OID)
Magnification factor
Penumbra
Focal spot geometry
Projection imaging
Oblique projections
Parallax
Projection radiography
Chest radiography
Skeletal radiography
Abdominal radiography
Portable radiography
Mobile X-ray systems
Screen-film radiography
Film characteristic curves
Intensifying screens
Computed radiography (CR)
Digital radiography (DR)
Direct-conversion detectors
Indirect-conversion detectors
Flat-panel detectors
Amorphous selenium detectors
Amorphous silicon detectors
Scintillator detectors
Cesium iodide detectors
Photostimulable phosphor plates
Pixel size
Pixel pitch
Detector sampling
Gas-filled detectors
Scintillation detectors
Semiconductor detectors
Photodiodes
CCD detectors
CMOS detectors
Flat-panel detector arrays
Detector efficiency
Detective quantum efficiency (DQE)
Quantum detection efficiency
Detector lag
Detector saturation
Dead pixels
Spatial resolution
Contrast resolution
Temporal resolution
Signal-to-noise ratio (SNR)
Contrast-to-noise ratio (CNR)
Quantum noise
Electronic noise
Structured noise
Image sharpness
Image uniformity
Dynamic range
Exposure latitude
Modulation transfer function (MTF)
Point-spread function (PSF)
Line-spread function (LSF)
Edge-spread function (ESF)
Limiting spatial resolution
Frequency-domain image analysis
Quantum mottle
Photon statistics
Poisson statistics
Electronic noise
Anatomical noise
Noise power spectrum (NPS)
Signal transfer
Noise-equivalent quanta (NEQ)
Origin of scattered radiation
Scatter-to-primary ratio
Scatter degradation of contrast
Anti-scatter grids
Grid ratio
Grid frequency
Air-gap technique
Beam collimation
Scatter correction algorithms
Fluoroscopic imaging
Continuous fluoroscopy
Pulsed fluoroscopy
Image intensifiers
Flat-panel fluoroscopy
Automatic brightness control
Last-image hold
Digital subtraction fluoroscopy
Dose-rate control
Interventional fluoroscopy
DSA physics
Mask images
Logarithmic subtraction
Contrast enhancement
Temporal subtraction
Motion artifacts
Vascular X-ray imaging
Mammographic X-ray spectra
Molybdenum targets
Rhodium targets
Tungsten-target mammography
Breast compression
Mammography detectors
Mammographic contrast
Microcalcification detection
Automatic exposure control
Digital mammography
Digital breast tomosynthesis
CT X-ray generation
CT detector arrays
Projection data
Sinograms
CT reconstruction
Filtered back projection
Iterative reconstruction
Hounsfield units
CT number
CT spatial resolution
CT contrast resolution
Helical CT
Multidetector CT
Cone-beam CT
Dual-energy CT
Spectral CT
Photon-counting CT
Cone-beam geometry
Flat-panel CBCT
Reconstruction algorithms
Scatter in CBCT
Dental CBCT
Image-guided radiotherapy CBCT
Dual-energy radiography
Dual-energy CT
Material decomposition
Effective atomic number imaging
Virtual monoenergetic imaging
Spectral separation
Photon-counting detectors
Energy-resolving detectors
Threshold discrimination
Spectral X-ray imaging
Charge sharing
Pulse pile-up
K-edge imaging
Multi-energy imaging
X-ray phase shifts
Propagation-based phase contrast
Grating interferometry
Analyzer-based imaging
Edge illumination
Differential phase imaging
X-ray small-angle scattering
Grating-based dark-field imaging
Lung microstructure imaging
Multimodal X-ray imaging
Limited-angle tomography
Digital breast tomosynthesis
Projection acquisition
Slice reconstruction
Out-of-plane blur
Back projection
Filtered back projection
Fourier reconstruction
Algebraic reconstruction
Statistical reconstruction
Iterative reconstruction
Model-based iterative reconstruction
Deep-learning reconstruction
Image filtering
Noise reduction
Edge enhancement
Histogram processing
Window width
Window level
Image resampling
Image interpolation
Image segmentation
Image registration
Motion artifacts
Grid artifacts
Detector artifacts
Aliasing
Saturation
Beam-hardening artifacts
Ring artifacts
Metal artifacts
Partial-volume artifacts
Scatter artifacts
Exposure
Air kerma
Absorbed dose
Equivalent dose
Effective dose
Entrance-surface air kerma
Entrance-surface dose
Dose-area product (DAP/KAP)
CTDI
CTDIvol
Dose-length product (DLP)
Organ dose
Patient dose estimation
ALARA principle
Time–distance–shielding
Lead shielding
Structural shielding
Primary barriers
Secondary barriers
Scatter radiation protection
Occupational exposure
Patient protection
Diagnostic reference levels
Image-quality–dose trade-off
kVp optimization
mAs optimization
Filtration optimization
Collimation optimization
AEC optimization
Dose reduction techniques
Pediatric protocol optimization
X-ray tube output testing
kVp accuracy
Timer accuracy
mAs linearity
Output reproducibility
HVL measurements
Beam alignment
Collimator accuracy
Detector uniformity
Spatial-resolution testing
Contrast-resolution testing
AEC performance
Phantom imaging
Anthropomorphic phantoms
Image-quality phantoms
Contrast-detail phantoms
Resolution phantoms
CT phantoms
Mammography phantoms
Dosimetry phantoms
AEC detector systems
Exposure termination
Chamber selection
Patient thickness compensation
Detector-response calibration
Iodinated contrast agents
Barium contrast agents
K-edge absorption
Contrast enhancement
Energy dependence of contrast
Contrast-enhanced CT
DICOM
PACS
RIS integration
Image compression
Digital image storage
Image display
Monitor calibration
Spectral radiography
Spectral CT
Photon-counting CT
Phase-contrast imaging
Dark-field imaging
X-ray fluorescence imaging
X-ray diffraction imaging
Coherent-scatter imaging
AI-assisted radiography
Computer-aided detection
Computer-aided diagnosis
Deep-learning image reconstruction
Noise reduction
Super-resolution
Automated quality control
Dose optimization
Synthetic image generation
Quantitative CT
Bone mineral density
Tissue density measurements
Material characterization
Radiomics
Texture analysis
Chest imaging physics
Musculoskeletal imaging
Dental X-ray physics
Pediatric radiography
Trauma radiography
Gastrointestinal imaging
Cardiovascular X-ray imaging
Interventional radiology physics
Ultra-low-dose X-ray imaging
High-resolution X-ray detectors
AI-based reconstruction
Photon-counting detector development
Spectral material decomposition
Phase-contrast clinical imaging
Dark-field lung imaging
Dynamic X-ray imaging
Motion correction
Scatter correction
Monte Carlo simulation of X-ray imaging
Personalized patient dosimetry
Task-based image-quality assessment
Medical Physics → Diagnostic Imaging Physics → X-ray Imaging Physics → Radiography / Fluoroscopy / Mammography / CT / CBCT / Spectral Imaging / Photon-Counting Imaging / Phase-Contrast Imaging / Detector Physics / Image Quality / Dosimetry / Radiation Protection / Quality Assurance.